Cardiovascular
Case TypeClinical Cases
AuthorsE.Rakhtawane, J. Steiner, N.Bouzegaou, G.Chedid, J.C. Le Van An .
Patient55 years, male
A detailed history elicited from the patient revealed that he had had a totally implantable venous device placed at another hospital one year previously for treatment of his gastric tumour, but then he had refused the chemotherapy and failed to return for follow-up. He had not advised other physicians of this situation. Apparently the catheter had fractured and migrated into the right pulmonary artery, where it remained until discovered incidentally on the chest radiograph performed at our hospital.
The fragment was successfully retrieved by a percutaneous endovascular technique, and another central venous catheter with implantable port was implanted for future chemotherapy.
Catheter fracture represents a rare problem among non-infectious complications following the insertion of totally implantable long-term central venous access systems. A literature survey revealed a total incidence of catheter fractures of 0-2.1%.
Catheter fatigue from prolonged use contributes to in situ fracture, fragmentation, and distal embolisation. The catheter fragments migrate distally along the blood stream, finally lodging in the vena cava, right atrium, right ventricle, or the main pulmonary artery or one of its branches. The final site of lodgment depends on the length, weight, and stiffness of the fragment.
The possible complications of centrally embolised foreign bodies include pericardial tamponade due to myocardial perforation, sepsis, endocarditis, thrombosis with subsequent pulmonary embolism, myocardial infarction, and arrhythmias.
According to Blair et al., mortality is highest when the catheter is located in the right side of the heart, lower when it is in the vena cava, and lowest when it is in the pulmonary artery.
Srihari et al. reported a case of a patient in whom a catheter fragment was retrieved from the pulmonary artery 11 years after embolisation without complications.
Reynen et al. described a 14-year history of central embolisation by a guide wire with no pulmonary symptoms for 12 years. Extraction was not attempted in this case as the guidewire was adherent to the vascular wall.
For extraction of iatrogenic foreign bodies causing central embolisation, percutaneous removal is preferable. Loop snares, Dormia baskets, and hooked guide wires and catheters may be used. Thoracotomy is indicated if nonsurgical removal fails.
The patient in this case was asymptomatic, with no adhesions of the catheter to the vessels walls. The catheter fragment was retrieved easily, without complications.
[1]
Thanigaraj S, Panneerselvam A, Yanos J. Retrieval of an IV catheter fragment from the pulmonary artery 11 years after embolization.
Chest 2000 Apr;117(4):1209-11. (PMID: 10767267)
[2] Fisher RG, Ferreyro R. Evaluation of current techniques for nonsurgical removal of intravascular iatrogenic foreign bodies. AJR Am J Roentgenol 1978;130:541-8. (PMID: 415566)
[3]
Iannelli A, Kianmanesh R, Msika S, Marano A, Levesque M, Grandjean M, Hay JM. Post-traumatic fracture and migration in the pulmonary artery of the catheter of a totally implantable venous access device. Unusual complication.
Minerva Chir 2001 Jun;56(3):303-6. (PMID: 11423798)
[4] Reynen K. 14-year follow-up of central embolization by a guidewire. N Engl J Med 1993;329:970-1. (PMID: 8361525)
[5] Blair E, Hunziker R, Flanagan ME. Catheter embolism. Surgery 1970;67:457-61. (PMID: 5413443)
URL: | https://www.eurorad.org/case/2158 |
DOI: | 10.1594/EURORAD/CASE.2158 |
ISSN: | 1563-4086 |